3HP Low Ambient Temperature Heat Pump for Cold Areas

Short Description:

The 3HP low ambient temperature air source heat pump can operate normally in the low-temperature environment of – 25 ℃,suitable for cold climate areas.
The hot air fan of the low-temperature air source heat pump adopts two-stage compressor with large suction capacity and significant defrosting capacity, so it can keep normal working in the low-temperature environment and provide air heating, ground heating and hot water for low-temperature areas.


Product Detail

Product Tags

Description of low ambient temperature heat pump

Type

Low Ambient Temperature Air Source Heat Pump

Housing Material

Plastic, galvanized Sheet

Storage / Tankless

Circulation Heating

Installation

Freestanding, Wall Mounted / Freestanding

Use

Hot Water/floor Heating/ fancoil Heating And Cooling

Heating Capacity

4.5-20KW

Refrigerant

R410a/ R417a/ R407c/ R22/ R134a

Compressor

Copeland, Copeland Scroll Compressor

Voltage

220V lnverter,3800VAC/50Hz

Power Supply

50/ 60Hz

Function

House Heating, Space Heating & Hot Water,Pool Water Heating, cooling And DHW

Cop

4.10-4.13

Heat Exchanger

Shell Heat Exchanger

Evaporator

Gold Hydrophilic Aluminum Fin

Working Ambient Temperature

Minus -25C- 45C

Compressor Type

Copeland Scroll Compressor

Color

White, Grey

Application

Jacuzzi Spa/ Swimming Pool,Hotel, Commercial And Industrial

Input Power

2.8-30KW

High Light

cold temperature heat pump, inverter air source heat pump

Different ambient temperatures will affect the service effect and the service life of the heat pump unit. Under the low ambient temperature in the north, it is necessary to use ultra-low temperature heat pump specially for low ambient temperature to ensure the normal start and operation of the heat pumps.. Solarshine ultra-low temperature air source heat pump adopts a special heat pump compressor, which can also operate stably, heat efficiently and prolong the service life of the unit under the condition of ultra-low temperature environment to -25℃.

specification of low ambient temperature heat pump

Model

KDR-03

KDR-05S

KDR-05-G

KDR-07-G

KDR-10-G

KDR-15

KDR-20

KDR-25

HP

3 HP

5 HP

5 HP

7HP

10HP

15HP

20HP

25HP

Power supply

220V/380V

220V

380V

380V

380V

380V

380V

380V

Input power

2.8

4.2

4.7

5.2

9.2

13

18.5

20.5

Heating power output at different ambient tem.

(20℃)

10.8

16.2

18

20

35.4

50

71.2

78.9

(6/7℃)

9

13.7

15.3

16.9

30

42.3

60

66.6

(-6/7℃)

6.9

10.3

11.5

12.7

22.5

319

453

50.2

(-15℃)

5.9

8.8

9.9

10.9

19.3

273

38.9

43

(-20℃)

5.2

7.8

8.7

9.6

17

24

34.2

37.9

Cooling power output

8.0

12.0

13.4

14.8

26.2

37.1

52.7

68.4

Fan outlet direction

Side

Side

Side

Side

Side

Side

Top

Top

V\faler connection

DN25

ON25

DN25

DN25

DN32

DN40

DN50

DN50

Fluid rate(M3/H)

2-3

4-5

5-6

5-7

7-10

12-15

15-20

20-25

Dimen -sion

(MM)

1152

1190

1190

1190

1350

1350

1800

1800

(MM)

422

425

425

425

645

645

1100

1100

(MM)

768

1240

1240

1240

1845

184S

2100

2100

WEIGHT (kg)

130

180

160

220

310

355

630

780

Why can air source heat pump work stably at - 25 ?

Many people's misunderstanding of air source heat pump mainly focuses on whether it can operate stably at low ambient temperaturemainly because they still stay in their previous understanding of ordinary heat pumps and lack sufficient understanding of low-temperature heat pumps.

The core component that causes the performance difference between low-temperature heat pump and ordinary heat pump is compressor. The reason why the low-temperature heat pump can operate normally under lower ambient temperature is to solve several problems encountered by the conventional heat pump - insufficient heating capacity, low cop and unstable operation caused by low evaporation temperature, low suction flow, large compression ratio and high exhaust temperature.

The first is the internal structure design. The scroll profile of the low-temperature heat pump compressor is designed larger, which means that under the condition of lower evaporation temperature, the low-temperature heat pump can obtain higher working efficiency and lower evaporation temperature working range to adapt to the working environment with large temperature difference.

Application Cases


  • Previous:
  • Next:

  • Write your message here and send it to us