3- 50Hp Swimming Pool Heat Pump for Large Commercial Pool

Short Description:

SolarShine’s 3- 50Hp swimming pool heat pumps are high quality products designed for indoor and outdoor large commercial swimming pools. 


Product Detail

Product Tags

HousingMaterial: Plastic, galvanized Sheet Storage/ Tankless: Circulation Heating
Installation: Freestanding,Wall Mounted/Freestanding Use: Swimming Pool Water Heating
Heating Capacity: 4.5- 20KW Refrigerant: R410a/ R417a/ R407c/ R22/ R134a
Compressor: Copeland Scroll Compressor Voltage: 220V~ lnverter, 3800VAC/50Hz
Power Supply: 50/ 60Hz Function: Pool Water Heating
High Light: swimming pool heat pump, pool heat pump heater, air source pool heat pump
9 air source swimming pool heat pump

The air source swimming pool heat pump unit can keep the water temperature of the swimming pool within the comfortable temperature range 28- 30ºC. The power of this series of products is from 1.5Hp- 2Hp for personal small pool, 3Hp- 30Hp for big commercial pool. 

8 air source swimmimg pool heat pump
swimming pool heat pump 888
Swimming pool heat pump units specifications
MODEL   KSW-3 KSW-5 KSW-6 KSW-10 KSW-12 KSW-20 KSW-25
Rated heating yielding KW 13 21 25 45 55 85 105
Kcal/h 11,180 18,060 21,500 38,700 47,300 77,400 90,300
BTU 44,353 71,647 85,295 153,531 187,649 290,003 358,239
Input power KW 2.6 4.4 5 8.8 11 17.5 22
Operation current A 5 7.7 8.9 16.1 20.7 31.3 40.8
Quantity of compressor Piece 1 1 1 2 2 2-4 2-4
Power demand   220/380V 380V/3N    
Compressor Full Enclosure scroll vortex
Type of heat exchanger Titanium tube heat exchanger
Quantity of fan   1 1 1 2 2 2 2
Fan's input power W 90 250 250 250x2 250x2 550x2 750x2
Fan's rotation speed RPM 850 830 830 830 830 930 930
Grade of water resistance 1PX4
Ventilation Top of heat pump units
pathway  
Type of refrigerant R22/R407C/R417A/R410A
Noise dB(A) 55 58 58 61 61 62 63
Connection s   DN40 DN40 DN40 DN50 DN50 DN80 DN80
Water flow m3/h 4 6 8 12 14 23 28
External dimension (L/W/H) mm 655/695/810 710/710/1 010 710/710/10 10 1450/710/118 0 1440/800/ 1380 1800/1100/2 150 2000/800/1380
Packing size (L/W/H) mm 685/725/940 740/740/1 140 740/740/11 40 1480/740/131 0 1470/830/ 1510 1830/1130/2 280 2030/1130/2280
Net weight kg 100 180 200 280 310 630 780
Gross weight kg 105 188 208 295 326 662 800
Work environment for tests of rated heat yield: temperatures of dry/wet balls which are placed outdoor 24°C/19°C. Incoming hot water temperature is 27°C.
Due to the machinery innovation or technical modifications, the model and parameter, the performance of the modified products
will be subject to changes without prior notice. Please refer to the specific products or models for details.  
structure of air source heat pump
16 swimming pool heat pump sample

Advantages:

1. Durable patent titanium heat exchanger.
The advanced titanium heat exchanger can stand up to the corrosive effects of salts and chlorine in swimming pool water. The heavy PVC shell of the titanium heat exchanger has great resistance to the erosion of chlorine ion in water.

2. Full DC Inverter Technology on the compressor.
With the DC full inverter technology, our full enclosure scroll vortex compressor enable the heat pump adjust its strength from 10% to 90% according to you requirements when the unit is heating swimming pool. The unit can operate economically and more efficient.

3. Low Noise Running.
The compressor can keep running in low noise as our copper pipe connections process design is excellent, which makes the refrigerant flow smoothly and effectively reduces the vibration of the compressor.

4. Saving Cost.
Comparing with traditional water heater, heat pump can save 65-80% of running cost.

5. Environmental Protection
Using R410 A or R32 refrigerants, no waste gas, no CO2 emissions, no pollution, no waste discharge.

6. Safety use.
No leakage risk, hydropower separation, the units can keep working safety.

How to size your heat pump and select the right one for your swimming pool?

We have many models of commercial swimming pools for your options, here are some information for your reference:

Data needed:
1. Specific information of the project location;
2. Basic information of the swimming pool (such as size, water depth, water temperature, indoor or outdoor, etc.).
3. Basic information of the swimming pool (such as area, floor height, glass surface, etc.).
4. Location of the machine room (and whether the power capacity is sufficient, etc.).
5. Unit placement.

Note: The initial heating time of competitive and special swimming pools should be 24- 48h; The time of filling water in the secondary pool should not exceed 48h, and the time of filling water in the recreational and water swimming pools for the first time should not exceed 72h.

Calculation of pool water heating, heat loss and water replenishment:

When heating the pool water, it is divided into two cases: one is the initial heating of the pool water, and the other is the heating of the pool water.

Constant temperature heating:

It must be clear that the selection of swimming pool machine for swimming pool water heating is based on the initial heating load, and the constant temperature heating load of the swimming pool, take the maximum load for unit selection.

Calculation of constant temperature heating of swimming pool water:

The heat required for pool water heating shall be the sum of the following heat consumption:

1. Heat loss from evaporation of pool water surface;

2. Heat conduction loss of tank wall and bottom and heat loss of pipeline and equipment;

3. Make up the heat required for heating fresh water.

Application cases:

application cases of swimming pool heat pump

  • Previous:
  • Next:

  • Write your message here and send it to us